Magnetization curves of 9 ferromagnetic materials, showing saturation. 1.Sheet steel, 2.Silicon steel, 3.Cast steel, 4.Tungsten steel, 5.Magnet steel, 6.Cast iron, 7.Nickel, 8.Cobalt, 9.Magnetite[1]

Magnetic Stainless Steel Parts Tray. Magnetic Stainless Steel Parts Tray $ 14 99. Add to Cart Add to My List. 81mm Round Magnet. 81mm Round Magnet $ 5 29. Master Magnetics 22018 at $9.99. Add to Cart Add to My List. Neodymium Bar magnets with widths & Lengths 1/2” - 1 “ Bar Magnet Gauss 12,100 - 14,800 3 Layer Coatings, Epoxy & Plastic coatings Bar Magnet W/ Countersunk Holes Pull Forces 2.3 - more than 121 lbs. 1 Pair N/S Magnets w/Adhesive Tab 1/2 in x 1/8 in Neodymium Magnet Discs Great bottle cap magnets for necklaces. Pull force: 6.6 lbs Magnetized through 1/8' 1 pair strong magnet discs with 3M clear adhesive and eas.

Seen in some magnetic materials, saturation is the state reached when an increase in applied external magnetic fieldH cannot increase the magnetization of the material further, so the total magnetic flux density B more or less levels off. (It continues to increase very slowly with the field due to paramagnetism.) Saturation is a characteristic of ferromagnetic and ferrimagnetic materials, such as iron, nickel, cobalt and their alloys. Different ferromagnetic materials have different saturation levels.

Capitol Hill Magnet 1-8 School

Description[edit]

Saturation is most clearly seen in the magnetization curve (also called BH curve or hysteresis curve) of a substance, as a bending to the right of the curve (see graph at right). As the H field increases, the B field approaches a maximum value asymptotically, the saturation level for the substance. Technically, above saturation, the B field continues increasing, but at the paramagnetic rate, which is several orders of magnitude smaller than the ferromagnetic rate seen below saturation.[2]

The relation between the magnetizing field H and the magnetic fieldB can also be expressed as the magnetic permeability: μ=B/H{displaystyle mu =B/H} or the relative permeabilityμr=μ/μ0{displaystyle mu _{r}=mu /mu _{0}}, where μ0{displaystyle mu _{0}} is the vacuum permeability. The permeability of ferromagnetic materials is not constant, but depends on H. In saturable materials the relative permeability increases with H to a maximum, then as it approaches saturation inverts and decreases toward one.[2][3]

Different materials have different saturation levels. For example, high permeability iron alloys used in transformers reach magnetic saturation at 1.6–2.2teslas (T),[4] whereas ferrites saturate at 0.2–0.5T.[5] Some amorphous alloys saturate at 1.2–1.3T.[6]Mu-metal saturates at around 0.8T.[7][8]

Due to saturation, the magnetic permeability μf of a ferromagnetic substance reaches a maximum and then declines

Ceramic Round Disc Magnet 1/8 Thick

Explanation[edit]

Ferromagnetic materials (like iron) are composed of microscopic regions called magnetic domains, that act like tiny permanent magnets that can change their direction of magnetization. Before an external magnetic field is applied to the material, the domains' magnetic fields are oriented in random directions, effectively cancelling each other out, so the net external magnetic field is negligibly small. When an external magnetizing field H is applied to the material, it penetrates the material and aligns the domains, causing their tiny magnetic fields to turn and align parallel to the external field, adding together to create a large magnetic field B which extends out from the material. This is called magnetization. The stronger the external magnetic field H, the more the domains align, yielding a higher magnetic flux density B. Eventually, at a certain external magnetic field, the domain walls have moved as far as they can, and the domains are as aligned as the crystal structure allows them to be, so there is negligible change in the domain structure on increasing the external magnetic field above this. The magnetization remains nearly constant, and is said to have saturated.[9] The domain structure at saturation depends on the temperature.[9]

Effects and uses[edit]

Saturation puts a practical limit on the maximum magnetic fields achievable in ferromagnetic-core electromagnets and transformers of around 2 T, which puts a limit on the minimum size of their cores. This is one reason why high power motors, generators, and utility transformers are physically large; to conduct the large amounts of magnetic flux necessary for high power production, they must have large magnetic cores. In applications in which the weight of magnetic cores must be kept to a minimum, such as transformers and electric motors in aircraft, a high saturation alloy such as Permendur is often used.

In electronic circuits, transformers and inductors with ferromagnetic cores operate nonlinearly when the current through them is large enough to drive their core materials into saturation. This means that their inductance and other properties vary with changes in drive current. In linear circuits this is usually considered an unwanted departure from ideal behavior. When ACsignals are applied, this nonlinearity can cause the generation of harmonics and intermodulation distortion. To prevent this, the level of signals applied to iron core inductors must be limited so they don't saturate. To lower its effects, an air gap is created in some kinds of transformer cores.[10] The saturation current, the current through the winding required to saturate the magnetic core, is given by manufacturers in the specifications for many inductors and transformers.

On the other hand, saturation is exploited in some electronic devices. Saturation is employed to limit current in saturable-core transformers, used in arc welding, and ferroresonant transformers which serve as voltage regulators. When the primary current exceeds a certain value, the core is pushed into its saturation region, limiting further increases in secondary current. In a more sophisticated application, saturable core inductors and magnetic amplifiers use a DC current through a separate winding to control an inductor's impedance. Varying the current in the control winding moves the operating point up and down on the saturation curve, controlling the alternating current through the inductor. These are used in variable fluorescent lightballasts, and power control systems.[11]

Magnet 1809

Saturation is also exploited in fluxgate magnetometers and fluxgate compasses.

In some audio applications, saturable transformers or inductors are deliberately used to introduce distortion into an audio signal. Magnetic saturation generates odd-order harmonics, typically introducing third and fifth harmonic distortion to the lower and mid frequency range.[12]

See also[edit]

References[edit]

  1. ^Steinmetz, Charles (1917). 'fig. 42'. Theory and Calculation of Electric Circuits. McGraw-Hill.CS1 maint: ref=harv (link)
  2. ^ abBozorth, Richard M. (1993) [Reissue of 1951 publication]. Ferromagnetism. AN IEEE Press Classic Reissue. Wiley-IEEE Press. ISBN0-7803-1032-2.CS1 maint: ref=harv (link)
  3. ^Bakshi, V.U.; U.A.Bakshi (2009). Basic Electrical Engineering. Technical Publications. pp. 3–31. ISBN81-8431-334-9.
  4. ^Laughton, M. A.; Warne, D. F., eds. (2003). '8'. Electrical Engineer's Reference Book (Sixteenth ed.). Newnes. ISBN0-7506-4637-3.CS1 maint: ref=harv (link)
  5. ^Chikazumi, Sōshin (1997). 'table 9.2'. Physics of Ferromagnetism. Clarendon Press. ISBN0-19-851776-9.CS1 maint: ref=harv (link)
  6. ^USA 5126907, Yoshihiro Hamakawa, Hisashi Takano, Naoki Koyama, Eijin Moriwaki, Shinobu Sasaki, Kazuo Shiiki, 'Thin film magnetic head having at least one magnetic core member made at least partly of a material having a high saturation magnetic flux density', issued 1992
  7. ^'Shielding Materials'. K+J Magnetics. Retrieved 2013-05-07.
  8. ^'Mumetal is one of a family of three Nickel-Iron alloys'. mumetal.co.uk. Archived from the original on 2013-05-07. Retrieved 2013-05-07.
  9. ^ ab'Magnetic properties of materials'(PDF). unlcms.unl.edu. Retrieved 2016-03-16.
  10. ^Rod, Elliott (May 2010). 'Transformers - The Basics (Section 2)'. Beginner's Guide to Transformers. Elliott Sound Products. Retrieved 2011-03-17.CS1 maint: ref=harv (link)
  11. ^Choudhury, D. Roy (2005). '2.9.1'. Modern Control Engineering. Prentice-Hall of India. ISBN81-203-2196-0.CS1 maint: ref=harv (link)
  12. ^'The Benefits of Harmonic Distortion (HMX)'. Audient Help Desk. Retrieved 2020-07-16.